Multiclamp 700b user manual

I am running igor on a windows os and i have a nidaq board that igor is already communicating with. Until now, system control of multiclamp amplifiers was limited to 32bit matlab and was. Sep 07, 2016 multiclamp 700b microelectrode amplifier user guide. Axopatch 200b when handling the headstage input since this will upset the thermal equilibrium. Axon multiclamp 700a amplifier patch clamp w 2 cv7a headstages pred 700b unit2 we have a total of 7 of these axon multiclamp 700a amplifiers systems.

This amplifier is used, and in excellent condition. Axon multiclamp 700a commander software was tested both in windows 7 and 10, 32bit and 64bit versions and it it works without problems. Amplifier axon multiclamp 700a theory and operation 159 pages computercontrolled microelectrode amplifier amplifier axon digidata 22a operators manual 32 pages. This technique is ideal for the evaluation of important.

Has anyone used the axon multiclamp 700a with windows 7. Patchclamp amplifier multiclamp 700b molecular devices. Second scaled output with signal conditioning usb communication replaces the previous rs232 support for bilayer headstage user defined control sensitivity fine, medium, coarse improved current clamp holding and offset resolution. Is anyone familiar with getting simultaneous extracellular. Multiclamp 700b amplifier the multiclamp 700b microelectrode amplifier is a versatile, computercontrolled microelectrode amplifier designed for patch voltageclamp resistivefeedback, four ranges or highspeed current clamp voltagefollower, three ranges recording within the same headstage. Multiclamp 700b microelectrode amplifier kf technology. Theory and operation axon multiclamp 700b theory and operation 172 pages. Can anybody help me to fix this problem with multiclamp 700b. Ion channels an ion channel is a group of proteins that. View and download axon multiclamp 700b theory and operation online. Seal test with variable amplitude and frequency fastslow electrode capacitance compensation automatic manual whole cell capacitance compensation automatic manual. Molecular devices multiclamp 700b amplifier automate.

For more information, visit our website or call axon technical support. Axon multiclamp 700b theory and operation pdf download. The worlds smallest integrated patch clamp amplifier and data acquisition system for wholecell and singlechannel recordings. Used axon instruments multiclamp axon multiclamp 700a. Axon multiclamp 700b computercontrolled current and patch. Application of automated imageguided patch clamp for the. Instead of the traditional front panel knobs and switches, the multiclamp 700b amplifier is controlled by the multiclamp 700b commander, a. Although the system meaning both the automated patch clamp system and the standalone data acquisition system can work with a variety of patch clamp amplifiers, it was designed with multiclamp amplifiers from molecular devices in mind. I am using it for patch clamp in hippocampal neurons. Warning shipping the axopatch 200b the axopatch 200b is a solidly built instrument designed to survive shipping around the world. Patch clamp electrophysiology, voltage clamp, action. Prepare acute brain slices, as described previously 10. A very low noise one channel amplifier enabling high bandwidth acquisitions for voltageclamp measurements. Download free user and service manuals for amplifier devices at.

How to change the signal units in pclamp with a multiclamp. Thus, bnctype input and output connections are necessary to communicate with a digitizing interface, oscilloscope or other recording device. The portfolio of amplifiers includes axopatch 200b for ultra lownoise singlechannel recordings, multiclamp 700b for wholecell voltageclamp and highspeed currentclamp recordings, and axoclamp 900a for twoelectrode voltageclamp and currentclamp recordings. I am not able to set the amplifier settings for the multiclamp 700b commander in order to get the exact holding voltage that i am entering. Place one brain slice in the center of the recording chamber. I thought that you could use igor to interface with and to control the commander for the multiclamp 700b amplifier. However, in order to avoid damage during shipping, the axopatch 200b must be properly packaged. Manuals and data sheets university of california, san diego. Our bestinclass instruments facilitate the entire range of patchclamp technique experiments from the smallest singlechannel to the largest macroscopic recordings. Axon instruments multiclamp 700a is a versatile computercontrolled amplifier capable of singlechannel, wholecell and ionselective electrode recordings, as well as voltammetry and amperommetry. Axon multiclamp 700b computercontrolled current and patch clamp amplifier for sale. Userspecified delay will allow you to perform creative new experiments. I0 mode in the command software is not the current clamp mode, its an automatic switch mode where you can define on what conditons the cell is to switch from vc to cc or vice versa.

Headstage cv7b patch clamp for multiclamp 700b quantity add to cart sku. Used axon instruments axon multiclamp 700a amplifier patch. The operation instructions for the multiclamp700b, digidata 1440b, sutter mpc 385 manipulators, and the clampex software package are all well documented. Axoclamp 900a and multiclamp 700b microelectrode amplifiers are softwaretelegraphed so microelectrode amplifier settings are stored with the data. Phoenix gold xs4600 amplifier owners manual pdf view. The multiclamp 700b amplifier comes standard with two independent cv7b headstages, each of which contains both currenttovoltage and voltagefollowing circuitry. Fens forum 2020 july 11 thru 15, 2020, glasgow, united kingdom. Axon multiclamp 700a amplifier patch clamp w 2 cv7a. Axon multiclamp 700b the multiclamp 700b microelectrode amplifier combines leading edge electronics design and a wealth of features and functions with an intuitive user interface that simplifies the creation of complex protocols. Stabilize the slice with a slice holddown, or harp. Axon multiclamp microelectrode amplifier manual download. Switch modes conditionally instantly switch recording modes by using the membrane potential as the trigger. In order to maintain the membrane potential at a consistent level, multiclamp 700b will automatically inject compensatory current over a user defined time course. Download pdf versions of our multiclamp amplifier manuals.

An additional usb port is required if the optional softpanel is used to control the amplifier. The signals for the multiclamp 700b amplifier molecular devices are sent to and from two computer interface boards. The multiclamp 700b microelectrode amplifier offers highquality voltage and currentclamp capability with fast mode switching and oscillation suppression, all under convenient computer control. Axon instruments patchclamp systems molecular devices. Please refer to the user manual of the optical system in use for the alignment procedures. Before we begin, switch on your multiclamp 700b and open multiclamp commander. Axon multiclamp 700b manuals manuals and user guides for axon multiclamp 700b. This versatile amplifier is capable of singlechannel and wholecell voltage patch clamp, highspeed current clamp sharp electrode or field potentials, ionselective. Overload problem in multiclamp 700b i am using multiclamp 700b and pclamp10 for my extracellular recording experiments. The softpanel is essentially a hardware extension of the multiclamp 700b commander software. Download a pdf version of the axon axopatch users guide. Rather, the purpose of this manual is to provide tutorials and detailed information about the design and operation of the multiclamp 700b amplifier as a whole. Although the multiclamp 700b is a computercontrolled amplifier, your mouse is not the only means of controlling the instrument. Headstage cv7b patch clamp for multiclamp 700b automate.

Multiclamp 700b university of california, san diego. And sometimes when i did pipette offset, the holding voltage just suddenly. The multiclamp 700b contains no front panel knobs and switches. Preset a voltage threshold in currentclamp mode, and multiclamp 700b will automatically switch to voltageclamp when the membrane potential reaches that voltage level.

Also if i set the holding voltage to say a set value of 60mv then for that setting of the amplifier the potential that we want to set gets multiplied by a factor of 10 or so. Experience the identifiably different spectramax id3 multimode microplate reader. The multiclamp 700b is the successor to the multiclamp 700a. Together with its extensive set of signal conditioning features, the multiclamp 700b amplifier is the choice for a large variety of experimental needs.

It was tested, cleaned and comes with day warranty. Multiclamp 700a manuals and user guides for axon multiclamp 700a. Axon commander consolidates all of your digital evidence in one secure, onpremise location. For obtaining field recording, the gain is set at 500x and the bessel is set at 200 hz. Download a pdf version of the axon axopatch user s guide. The nidaq usb6211 national instruments board is used to send signals to the amplifier during autopatcher operation, and the digidata 1440a is used for recording with commercial software pclamp molecular devices once whole cell is obtained. Single channel recording the patchclamp technique involves a glass micropipette forming a tight gigaohm seal multiclamp 700b the cell membrane. Multiclamp 700b microelectrode amplifier a computercontrolled amplifier for currentclamp and voltageclamp applications powerful features the multiclamp 700b amplifier uses either an external trigger command or user programmable voltage threshold for rapid, automatic modeswitching between current and voltageclamp. Whenever, you are rebooting the computer, or starting. Hi all, i am seeking for your help with the multiclamp 700b.

A usb port is required to connect the multiclamp 700b. Multiclamp 700b axoclamp 900a digidata 1200b manual digidata 1440a manual. User specified delay will allow you to perform creative new experiments. Multiclamp 700b microelectrode amplifier molecular devices. We have 1 axon multiclamp 700b manual available for free pdf download. The multiclamp 700b amplifier from molecular devices is a computercontrolled. Granted the multiclamp 700b is a double amplifier but one could buy almost 6. Some functions are common to both voltage and current clamp. The multiclamp 700b amplifier from molecular devices is a computercontrolled microelectrode current and voltage clamp amplifier for electrophysiology and electrochemistry. Axon multiclamp 700a patch clamp amplifier, two cv7a. This design allows the user to rapidly switch between patch clamp recording and true highspeed current clamp recording. Preset a voltage threshold in currentclamp mode, and multicclamp700b will automatically switch to voltageclamp when membrane potential reaches that voltage level.

Molecular devices multiclamp 700b amplifier automate scientific. Multiclamp 700b axoclamp 900a 2012 for research use only. Download free axopatch 700b manual bittorrentmonitor. Designed to meet the evidence management needs of agencies in regions without reliable highspeed internet access, commander delivers many of the same features as cloudbased axon evidence. The multiclamp 700b microelectrode amplifier from molecular devices is a computercontrolled microelectrode current and voltageclamp amplifier for electrophysiology and electrochemistry. Automated wholecell patch clamp electrophysiology of.

Flow of recording signal axoclamp 900a multiclamp 700b axopatch 200b biological signals. Knobs and buttons replace mouse or keyboard control. The multiclamp 700b amplifierenables researchers to perform experiments that were previously not possible using a single amplifier. Multiclamp 700b amplifier automatically injects a compensatory. I am using multiclamp 700b i am using multiclamp 700b too along with pclamp 9. Although this manual has been prepared with every precaution to ensure. It was tested, cleaned and comes with 180day warranty. With clampex 11 software, the latest bnctelegraphed amplifiers are also supported. Molecular devices axon multiclamp 700b for sale labx. The multiclamp 700b is essentially an analog input output instrument, similar to conventional amplifiers by axon instruments. The multiclamp 700b commander program runs on the us windows xp2000me98 operating systems, as well as macintosh os x, version 10. The multiclamp 700b comes standard with two identical but independent cv7b headstages, each of which contains both currenttovoltage and voltagefollowing circuitry. Currentclamp is commonly used to inject simulated, but realistic current waveforms into a cell, and monitor membrane effect. Multiclamp 700b manuals and user guides for axon multiclamp 700b.

We have 1 axon multiclamp 700a manual available for free pdf download. Multiclamp 700b microelectrode amplifier user guide. Multiclamp 700b highspeed current clamp molecular devices. Together with its extensive set of signal conditioning features, the multiclamp 700b ampli. To measure the membrane potential, the multiclamp 700b and axoclamp 900a both monitor voltage drop initiated by current injection along an inseries resistor.

In current clamp mode, but with i0, i use a gain, and feedback resistor rf500 megaohm. Axon instruments appears to be the gold standard theyre the only amplifiers ive ever used but the multiclamp 700b. Overload problem in multiclamp 700b scientist solutions. Dec 12, 2019 axon multiclamp 700b microelectrode amplifier. Im looking to purchase a new patch clamp amplifier.

Wholecell patch clamp electrophysiology of neurons is a gold standard technique for highfidelity analysis of the biophysical mechanisms of neural computation and pathology but it requires great skill to perform. In its default configuration, the input command to the patch amplifier is sent from the nidaq board for automated patch clamping. Multiclamp 700b from molecular devices formerly axon instruments if you have a different amplifier or one of these amplifiers with a different headstage, consult the manual with the setup instructions. Experienced and inexperienced researchers alike are advised to read this manual thoroughly and to familiarize themselves with the instrument using model electrodes i. Part list for autopatcher setup patch clamp amplifier. If commander opens in demo mode reported in the title bar, you will need to connect the amplifier to the software.

159 829 105 934 1234 862 1413 574 1111 290 195 1449 592 596 1095 137 1277 935 752 1444 230 1474 553 367 887 900 1079 542 1120 140 227 453 207 593 834 1104 620